.Design and implementation of a non-mechanical scanning F-P type laser warning method[J].Optoelectronics Letters,2010,6(5):384-387
Design and implementation of a non-mechanical scanning F-P type laser warning method
沈洪斌
Department of Optics and Electronic Engineering, Mechanical Ordnance Engineering College;
Abstract:
      In the laser warning system, a non-mechanical scanning Fabry-Perot (F-P) type laser warning method and its crucial component-laser incident sensor design method are brought out, and the F-P etalon with the interferometric filter combination is adopted. For the incident laser pulse with a certain wavelength, the transmittance difference of the interferometric filters is independent with polarization of incident light, and descends almost linearly as the incident angle gets wider. A laser incident angle sensor experimental platform is built up, and the experiment is carried out with a given laser range finder. As the results indicate, when the incident angle is less than 5°, the transmittance difference measured by the laser angle sensor is significantly lower, and the deviation is more than 10%. While the incident angle is greater than 10°, the deviation is reduced significantly.
Hits: 4202
Download times: 240
View Full Text    Download reader